In addition to the same benefits as BinMaster's standard capacitance probe models, the PROCAP I-FL and II FL are designed for "no probe instrusion" in space-constrained areas or applications where material flow or bridging may damage a standard probe. FL models can be mounted on a bin wall, conveyor housing, or a chute. The face of the bottom of the FL serves as the capacitance sensor. With unsurpassed sensitivity of 0.5 pF, the PROCAP I-FL and II-FL are appropriate for use with a wide variety of powders, solids, liquids, and slurries.
PROCAP I FL Power Requirements: Universal power supply 24 to 240 VAC/VDC
PROCAP II FL Power Requirements: Selectable 115/230 VAC
Output Relay: DPDT 10 Amp at 250 VAC
Ambient Temp: -40°F to +185°F (-40°C to +85°C)
Process Temp: 150°F standard (65°C); 450°F high temp (232°C)
Pressure: 250 PSI Approvals & Certifications: Listed for Class II, Groups E, F & G Hazardous Locations. Units also available in Class I, Groups C & D.
Enclosure Type: NEMA 4X, 5, 9 & 12. Units also available in Class I, Groups C & D
Housing Enclosure: Die cast aluminum, USDA approved powder coat finish
Mounting: Flush